SY031 strain gauge bridge meter is a battery powered hand held instrument. The 4.5 digit 24 bit instrument displays measurements from load cells and other strain gauge bridge transducers. The load meter offers peak and trough hold and up to 16 channels of stored calibration data, stored in non-volatile memory. The  meter is easy to calibrate by applying a known load,by shunt calibration and with fine adjustment facility to correct for drift over time in transducers. A TEDS enabled transducer version is also available. The LCD displays are 10.2mm tall and give user friendly prompts to ease set up and calibration.  The instrument displays scaled readings  with peak and trough capture facility that can be switched in as required.   With the option of RS232 added  the unit can output readings at user programmable timed intervals. We can offer a range of connectors to suit user requirement.  Other options include a rubber holster a leather clear soft fronted case.  This unit can also paired with a load cell and calibrated to Namas standards to use as a calibration set.  User to specify load cell type. 2 x AA batteries give 40 hours operation. There is no battery status indicator.  If the unit will switch on it will measure accurately.  Case ABS Grey size 152L x 83W x 34D mm

Component ID SY031
Name SY031 Portable Load Meter
Base Price £160.00

Product Options

Channel 1

mV/V (+£0.00)
4-20mA (+£5.00)
TEDS 'transducer electronic datasheet' 4-20mA (+£25.00)
TEDS electronic data sheet mV/V (+£25.00)

Enclosure Options

None (+£0.00)
Rubber holster (+£12.74)
Leather clear window case (+£20.00)

Connector Options

4-Pin (+£0.00)
Specify (at the end of Order Process) (+£0.00)
5-Pin (+£6.00)

Comms Options

None (+£0.00)
RS232 comms.stereo jack socket includes serial lead (+£54.49)
RS232 comms. 9 way Dtype +serial lead (+£60.49)

Please login or Register if you wish to order this product.

Frequently Asked Questions

click to read answer Low Battery Indication / Unit does not turn on
If the battery is low the loadmeter will not turn on.
click to read answer Error message when calibrating to known load
Connect the load to SY031 loadmeter and tare off current reading before calibrating unit, take note that the unit is not in Hold mode.
click to read answer If the batteries are low will measurement be accurate?
Yes. When the batteries are too low to give the transducer the required excitation voltage the instrument will not turn on. That is why there is no battery status indicator.